Type A, B, C or D FIBC

The four electrostatic types explained and compared: fabric, breakdown voltage, grounding and where each is permitted.

Ask our engineers about this specification →
PP woven fabric with conductive yarns used in anti-static FIBC STATIC SAFETY · IN-HOUSE TEST
PP woven fabric with conductive yarns for Type C and Type D FIBC
Type A–DElectrostatic classes
6 kVType B breakdown limit
≤10⁸ ΩType C resistance to earth
IEC 61340-4-4Test reference
The basics

One hazard, four responses

Type A, B, C and D describe how an FIBC behaves around static electricity — not its size, shape or strength. The classification is driven by the minimum ignition energy of your powder and by whether flammable gas or vapour is present. Always have the final choice confirmed by a safety engineer.

Type A

Constructed from standard polypropylene woven fabric without any electrostatic protection. Static charges can accumulate during filling and discharge of combustible powders and generate incendiary sparks. Strictly prohibited in flammable or explosive atmospheres.

Type B

Made from insulating fabric with a low breakdown voltage — typically no more than 4–6 kV — to prevent propagating brush discharges. Permitted only for dry combustible powders; never where flammable gases or vapours are present.

Type C

Interwoven conductive threads or fully conductive fabric, with all conductive components bonded together. Must be reliably earthed with a dedicated grounding cable during operation. Suitable for combustible dusts and flammable vapours.

Type D

Static-dissipative fabric using corona discharge to neutralise charge into the air without a ground connection, producing no sparks. Widely used with flammable dusts and vapours, provided the bag surface stays clean and free of conductive contaminants or coverings.

Comparison

Side by side

Type AType BType CType D
FabricStandard PPLow-breakdown insulating PPConductive yarn / fabricStatic-dissipative fabric
Breakdown voltageNo limit≤ 4–6 kVn/a — conductive pathCorona discharge, no earth
GroundingNot applicableNot applicableRequired, every fillNot required
Combustible dustNoYesYesYes
Flammable gas / vapourNoNoYesYes
Main failure modeIncendiary sparkBrush discharge if misusedUnearthed = unsafeDirty / coated surface
Decision

Specifying it

1 · Classify the material

Establish minimum ignition energy, dust class and whether solvents or vapours are present during filling.

2 · Check the site

If reliable earthing cannot be guaranteed at every filling station, a grounded Type C bag is not a safe default.

3 · Write it down

Put the type, grounding requirement and surface-cleanliness condition on the specification and the operator work instruction.

Related reading

Continue in the Knowledge Hub

Sewing operation on an FIBC production line
Construction detail
Conductive carbon-black FIBC bulk bag
Type C construction
Surface resistance measured on conductive fabric
Static testing

All knowledge topics →

Applying this to a real order?

Share your material, load and filling method. We will confirm the type, liner and attachment in a written specification.

Get a Quote